Fluitronic Power Units with Submersed Engine

Safety, operational efficiency and long term reliability. The GMV power units are one of the most important components of the GMV hydraulic lift system. A wide range of products allows the assembly of components for all types of elevator systems, suitable for residential as well as for industrial environments.

GL POWER UNIT

The GL power unit is characterized by a new, smaller-sized tank to gain space and to use a reduced quantity of oil.

The power unit features the same range of components as the traditional 3010 EN line, in order to guarantee excellent travel comfort and reliability.

Like all other GMV power units, the GL version may be equipped with the traditional distribution valve or with the more sophisticated electronic valves.

It is available with a pump flow rate from 25 to 180 l/min and is designed for hydraulic installations with a built-in machine room as it fits in our cabinet type C.

Technical Data 3010 NGV A3
50 Hz 60 Hz 50 Hz 60 Hz
2 poles – 1 phase 2 poles – 3 phases 2 poles – 3 phases 2 poles – 3 phases 2 poles – 3 phases
Engine power [kW] 2.9 ÷ 3.4 2.2 ÷ 14.7 2.2 ÷ 14.7 2.2 ÷ 14.7 2.2 ÷ 14.7
Nominal pump flow rate [l/min] 30 ÷ 55 25 ÷ 180 30 ÷ 180 55 ÷ 210 66 ÷ 216
Maximum static pressure [bar/MPa] 45 / 4,5
Minimum static pressure vacuum [bar/MPa] 12 / 1,2
Unladen weight [kg] max. 90
Total Fluid filling quantity [l] 120
Fluid quantity in circulation (used) [l] max. 75
Minimum Fluid (pump covering) [l] 45

POWER UNIT F1

The power unit F1 is part of the range of the GMV power units with a medium-sized tank, suitable for lift systems of 6-8 passengers and 6-7 stops. The particular design of the tank allows a reduced quantity of oil in circulation.

The power unit features the same range of components as the traditional 3010 EN line, in order to guarantee excellent travel comfort and reliability.

Like all other GMV power units, the F1 version may be equipped with the traditional distribution valve or with the more sophisticated electronic valves.

It is available with a pump flow rate from 25 to 210 l/min and is designed for hydraulic installations with a built-in machine room as it fits in our cabinet type A and B.

Technical Data 3010 NGV A3
50 Hz 60 Hz 50 Hz 60 Hz
2 poles – 1 phase 2 poles – 3 phases 2 poles – 3 phases 2 poles – 3 phases 2 poles – 3 phases
Engine power [kW] 3,4 2.2 ÷ 14.7 2.2 ÷ 14.7 2.2 ÷ 14.7 4.7 ÷ 14.7
Nominal pump flow rate [l/min] 30 ÷ 55 25 ÷ 210 30 ÷ 216 55 ÷ 210 66 ÷ 216
Maximum static pressure [bar/MPa] 45 / 4,5
Minimum static pressure vacuum [bar/MPa] 12 / 1,2
Unladen weight [kg] max. 100
Total Fluid filling quantity [l] 130
Fluid quantity in circulation (used) [l] max. 90
Minimum Fluid (pump covering) [l] 40

POWER UNIT 3010 EN TYPE T2, T3, T4

The power unit 3010 EN is designed to ensure maximal travel comfort in hydraulic systems. It is available with a wide range of possibilities in order to combine power, capacity and size, for meeting every demand. The mechanical valve 3010 EN is constantly involved in any moment of the travel of the elevator, in terms of speed, accelerations and decelerations, in order to guarantee a proper functioning of the lift to changing pressure and temperature conditions.

For large-scale elevators, the power units are provided in a double version, with a double valve and propulsion system.

For larger quantities of oil, tanks may be produced in double size or in a special design and it is possible to install the leveling to floor device.

By testing every single part of the unit, besides assuring the proper functioning of the power unit, a pre-calibration of the valve with parameters similar to its intended use, is carried out: the adjustments on-site will thus be simple and essential.

For large-sized elevators, the power units are provided in a double version, with the possibility of a double valve and propulsion system.

For larger quantities of fluid, it is possible to supply tanks in special dimensions.

Type

Tank

Valve type Valve block size Flow rate

[l/m]

Engine power

[kW]

Unladen weight [kg] Capacity [l]
min max min max Min. fluid Fluid quantity in circulation (used) Total filling fluid
T2 3010 1”1/4” 52 216 2,9 22,0 180 70 150 220
NGV A3 55 252 2,2
T3 3010 1”1/2” 180 432 9,5 44,1 270 100 300 400
NGV A3 1”1/4” 55 300 2,2 29,4
1”1/2” 360 432 14,7 44,1
T4 3010 2” 432 600 22,0 58,8 360 250 400 650
NGV A3 1”1/2 360 432 14,7 44,1
2” 500 600 22,0 58,8

POWER UNIT 3010 EN TYPE 2T2, 2T3, 2T4

For large-sized elevators, the power units are provided in a double version, with the possibility of a double valve and propulsion system. For larger quantities of fluid, it is possible to supply tanks in special dimensions.

Type

Tank

Valve type Flow rate

[l/m]

Weight without fluid [kg] Capacity [l]
min. max. Min. Fluid Fluid quantity in circulation (used) Total filling fluid
2T2 3010 52 216 390 140 300 440
2T3 3010 180 432 570 200 600 800
2T4 3010 432 600 750 500 800 1300

FLUITRONIC POWER UNITS MRL-T AND MRL-H

Power units for the machine room less systems. Like other GMV power units, the MRL-T and the MRL-H versions can:

  • be equipped with traditional distribution valves or with the more sophisticated electronic valves
  • operate with a synthetic-based ecological fluid, which is biodegradable > 70%, or with traditional mineral oil

Technical Data MRL-T power unit
3010 / NGV A3
50 Hz 60 Hz
2 poles – 3 phases 2 poles – 3 phases
Engine power [kW] 4.7 ÷ 18.4 4.7 ÷ 18.4
Nominal pump flow rate [l/min] 55 ÷ 210 66 ÷ 216
Maximum static pressure [bar/MPa] 45 / 4,5
Minimum static pressure vacuum [bar/MPa] 12 / 1,2
Unladen weight [kg] max. 100
Total Fluid filling quantity [l] 125
Fluid quantity in circulation (used) [l] max. 75
Minimum Fluid (pump covering) [l] 50