SECURING
It is NECESSARY to ensure the safety of users. There is a criminal liability in case of serious accidents in the hands of the building managers and the owners.
According to art. 40 of the Penal Code paragraph 2 (Italy) “Do not prevent an event that you have the legal obligation to prevent is equivalent to cause it”. As accident statistics show, hydraulic lifts are safe installations. However, they are machines subject to wear and therefore require checks and revisions. In recent years the importance of accident prevention has increasingly been understood.
The Machinery Directive 2006/42/EC introduced the concept that a single fault should not cause a dangerous condition and indicates that “Machinery must be designed, constructed and, if necessary, fitted with devices to prevent uncontrolled upward or downward movement of the carrier.” (6.4.1.).
The most recent standards have incorporated this requirement also in the field of lifts in relation to new lifts (amendment A3 to standard EN 81-2, now integrated in standard EN 81-20)by requiring that devices be provided to prevent uncontrolled movement of the cabin when the doors are open. Compliance with this standard has been implemented through the introduction of double safety locks on hydraulic valve assemblies. The matter has been standardized also in reference to the existing lifts with the standard EN 81.80.
MANY LIFTS IN SERVICE DO NOT GUARANTEE USERS THE MANDATORY LEVEL OF SAFETY FOR NEW LIFTS
DOUBLE SAFETY LOCK
The old hydraulic lifts are normally free of double safety locks and in some cases are also free of the gate.
In the hydraulic lifts installed before 2012, only the double safety provided by the shut-off valve (shutter) and the retraction system was foreseen. It is therefore evident that in these cases the safety is limited, because, in case of loss of the lift of blocking the flow, the catch after a certain time (about 20 minutes) stops working due to the heating of the engine and oil. As a result, double safety is lost, which can cause the cabin to move when the doors are open.
A similar situation could occur in the event of a lack of electricity, which would prevent the operation of the engine and therefore of the recovery system.
VALVE DLV
The DLV valve allows the introduction of double safety locks on valves manufactured by GMV or other manufacturers. It is an electrically driven non-return valve, which must be installed in series between the jack and the main distributor.
You can install the DLV valve in less than two hours.
VALVE ASSEMBLY REVISION
The general periodic revision of the valve assembly shall be carried out. GMV has the possibility, in the Novara plant, to offer this service for both valves and complete control units.
OIL REPLACING
Hydraulic oil after years of service is subject to deterioration and needs to be replaced. In compliance with recent regulations on environmental protection, it is advisable to replace mineral or synthetic oils with biodegradable Ecological Fluid. The Ecological Fluid GMV is a synthetic based hydraulic fluid with a biodegradability index >70%. In the event of accidental spills, it protects the owner of the lift from prosecution.
GMV considers it its duty to inform its customers of this and to raise awareness among all stakeholders. For this reason it has organized and is planning to organize in the future training to lift companies, verifiers of notified bodies and building managers on this issue.
GMV has the right products to meet this need and at a low cost.