FLUITRONIC DRY POWER UNITS
Safety, cost-effectiveness and reliability over time. GMV control units are one of the most important components of the GMV hydraulic lift. A wide range of products that allows the elevator operator to assemble any type of plant, from residential to industrial plants..

GL POWER UNIT

F1 POWER UNIT

3010 EN TYPE T2 POWER UNIT

3010 EN TYPE T3 POWER UNIT

3010 EN TYPE T4 POWER UNIT

3010 EN TYPE 2T2 POWER UNIT

FLUITRONIC MRL-T POWER UNIT

FLUITRONIC MRL-H POWER UNIT
GL POWER UNIT
The GL control unit is characterized by a new tank with a reduced volume, which allows for smaller dimensions and a reduction in the quantity of oil used.
The control unit has the same range of components that already characterize the traditional series 3010 EN guaranteeing the optimal characteristics of comfort and reliability demonstrated by these last.
Like the other GMV control units, the GL version can be equipped with a traditional distribution valve or with the most sophisticated electronic control valves.
It is available with pump flow from 25 to 180 l/min. and can be used in hydraulic systems with prefabricated machine room, as it can be inserted into our type C cabinet.
| Technical features | 3010 | NGV A3 | |||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | ||
| 2 poles – 1 phase | 2 poles – 3 phases | 2 poles – 3 phases | 2 poles – 3 phases | 2 poles – 3 phases | |
| Engine power[kW] | 2,9 ÷ 3,4 | 2,2 ÷ 14,7 | 2,2 ÷ 14,7 | 2,2 ÷ 14,7 | 2,2 ÷ 14,7 |
| Nominal flow rate pumps [l/min] | 30 ÷ 55 | 25 ÷ 180 | 30 ÷ 180 | 55 ÷ 210 | 66 ÷ 216 |
| Maximum static pressure [bar/MPa] | 45 / 4,5 | ||||
| Minimum static pressure at no load [bar/MPa] | 12 / 1,2 | ||||
| Unladen weight [kg] | max 90 | ||||
| Total filling fluid [l] | 120 | ||||
| Fluid circulating (useful) [l] | max 75 | ||||
| Minimum fluid (pump cover) [l] | 45 | ||||
F1 POWER UNIT
The F1 unit is part of the GMV range with a tank of intermediate size suitable for installations for 6-8 passengers at 6-7 stops. The special design of the tank results in a reduction in the amount of oil used.
The control unit has the same range of components that already characterize the traditional series 3010 EN guaranteeing the optimal characteristics of comfort and reliability demonstrated by these last.
Like the other GMV control units, the F1 version can be equipped with a traditional distribution valve or with the most sophisticated electronic control valves.
It is available with pump flow from 25 to 210 l/min. and can be used in hydraulic systems with prefabricated machine room, as it can be inserted in our versions of type A and B cabinets.
| Technical features | 3010 | NGV A3 | |||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | ||
| 2 poles – 1 phase | 2 poles- 3 phases | 2 poles – 3 phases | 2 poles – 3 phases | 2 poles – 3 phases | |
| Engine power [kW] | 3,4 | 2,2 ÷ 14,7 | 2,2 ÷ 14,7 | 2,2 ÷ 14,7 | 4,7 ÷ 14,7 |
| Nominal flow rate pump [l/min] | 30 ÷ 55 | 25 ÷ 210 | 30 ÷ 216 | 55 ÷ 210 | 66 ÷ 216 |
| Maximum static pressure [bar/MPa] | 45 / 4,5 | ||||
| Minimum static pressure at no load [bar/MPa] | 12 / 1,2 | ||||
| Unladen weight [kg] | max 100 | ||||
| Total filling fluid [l] | 130 | ||||
| Fluid circulating (useful) [l] | max 90 | ||||
| Minimum fluid (pump cover) [l] | 40 | ||||
3010 EN TYPE T2, T3, T4 POWER UNIT
Designed to ensure maximum ride comfort for passengers in hydraulic lifts, the 3010 EN control unit is offered with a wide range of power, flow and size combinations, The new system will be able to meet the different special requirements. At every stage of the race, the speed, accelerations and decelerations are controlled by the 3010 EN valve to ensure constant operation of the system in varying pressure and temperature conditions.
For large lifts the unit is offered in double version, with double valve and propulsion system.
In case of large quantities of oil it is possible to produce double or special tanks and the installation of the micro-leveling device.
By testing each unit produced, in addition to ensuring the correct operation of the control unit, the precalibration of the valve on parameters close to those of its final use: in this way the operations of adjustment in the site will be simple and essential.
For large lifts, the units are also offered in double version, with the possibility of a double valve and propulsion system.
In case of large quantities of fluid, special sizes can be provided.
| Tank Type | Valve Type | Size of valve block | Load Capacities [l/m] | Power [kW] | Dry weight [kg] | Capacity [l] | ||||
| min | max | min | max | Fluid min | Circulation fluid (useful) | Total fluid | ||||
| T2 | 3010 | 1”1/4 | 52 | 216 | 2,9 | 22,0 | 180 | 70 | 150 | 220 |
| NGV A3 | 55 | 252 | 2,2 | |||||||
| T3 | 3010 | 1”1/2 | 180 | 432 | 9,5 | 44,1 | 270 | 100 | 300 | 400 |
| NGV A3 | 1”1/4 | 55 | 300 | 2,2 | 29,4 | |||||
| 1”1/2 | 360 | 432 | 14,7 | 44,1 | ||||||
| T4 | 3010 | 2” | 432 | 600 | 22,0 | 58,8 | 360 | 250 | 400 | 650 |
| NGV A3 | 1”1/2 | 360 | 432 | 14,7 | 44,1 | |||||
| 2” | 500 | 600 | 22,0 | 58,8 | ||||||
3010 EN TYPE 2T2, 2T3, 2T4 POWER UNIT
For large lifts, the power units are offered in double version, with the possibility of a double valve and propulsion system. In case of large quantities of fluid, it is possible to provide special sizes.
| Tank type | Valve type | Load capacities [l/m] | Fluid free weight [kg] | Capacity [l] | |||
| min | max | Min fluid | Circulation fluid (useful) | Total fluid | |||
| 2T2 | 3010 | 52 | 216 | 390 | 140 | 300 | 440 |
| 2T3 | 3010 | 180 | 432 | 570 | 200 | 600 | 800 |
| 2T4 | 3010 | 432 | 600 | 750 | 500 | 800 | 1300 |
FLUITRONIC MRL-T E MRL-H POWER UNIT
The power units for machine-less systems. Like other GMV power units, the versions MRL-T and MRL-H can be:
- equipped with traditional distribution valves or the most sophisticated electronic control valves
- powered by synthetic-based ecological fluid with biodegradability > 70% or traditional mineral oil
| Technical features | MRL-T Power unit | MRL-H Power unit | ||
| 3010 / NGV A3 | 3010 | NGV A3 | ||
| 50 Hz | 60 Hz | 50 Hz | 50 Hz | |
| 2 poles – 3 phases | 2 poles – 3 phases | 2 poles – 3 phases | 2 poles– 3 phases | |
| Engine power [kW] | 4,7 ÷ 18,4 | 4,7 ÷ 18,4 | 2,2 ÷ 18,4 | 4,7 ÷ 18,4 |
| Nominal flow rate pump [l/min] | 55 ÷ 210 | 66 ÷ 216 | 25 ÷ 210 | 55 ÷ 210 |
| Maximum static pressure[bar/MPa] | 45 / 4,5 | 45 / 4,5 | ||
| Minimum static pressure at no load[bar/MPa] | 12 / 1,2 | 12 / 1,2 | ||
| Unladen weight [kg] | max 100 | max 110 | ||
| Total filling fluid [l] | 125 | 145 | ||
| Fluid circulating (useful) [l] | max 75 | max 80 | ||
| Minimum fluid (pump cover) [l] | 50 | 65 | ||